제품 상세 정보:
|
| 이름: | 맞춤형 테이블 운송 시뮬레이션 기계적 진동 테스트 셰이커 테이블 | 진동 테이블 (밀리미터): | 1000x800 |
|---|---|---|---|
| 진동 방향: | / 다우텀 위로 | 주파수 범위: | 5-60 Hz |
| 조정할 수 있는 변위 범위: | 0-2.6mmP-P | 받아들일 수 있는 가속 범위: | 0-11G |
| Max.Loading 중량: | 300kg | 작동 모드: | 고정된 /Random/Sweep |
| 전원: | AC 220V 50/60Hz | ||
| 강조하다: | customizable mechanical shaker table,vibration test shaker table,packaging transport simulation table |
||
Customizable Table Transportation Simulation Mechanical Vibration Test Shaker Table
Vibration Tester Specification
|
Model
|
RV8000
|
|
Vibration Table (mm) Lx W
|
1000 x 800
|
|
Frequency Range
|
5-60 Hz
|
|
Adjustable Amplitude (mmp-p)
|
0-2.6
|
|
Acceleration Range
|
0-11G
|
|
Max.Payload (kg)
|
300 |
|
Control Interface
|
IBM PC Serial port Rs232 9P/USB Port
|
|
Test Method
|
Fixed frequency,Sweep frequency(linear/logarithm),
multi-stage random
|
|
Waveform
|
Sine Wave
|
|
Vibration Direction
|
Up / Down |
|
Power Supply
|
AC220V 50/60Hz
|
Mechanical vibration test system has three testing modes: fixed frequency test, Sweep frequency test and multi-stage frequency test. These three tests provide the users the determination for vibration functional test, vibration durability test, package transporting test, resonance search, resonance dwell, stress screen, fatigue test and so on.
i) Fixed frequency test mode: firstly set the fixed testing frequency, amplitude and testing duration. The software will control the vibrating table according to the set parameters until the testing time is finish. Operating mode is shown in figure a. The test frequency and amplitude must be within the machine’s performance curve, or it cannot be tested.
ii)Sweep frequency test mode: firstly set the starting frequency, stop frequency, testing amplitude and sweep frequency duration. The software will control the vibrating table according to the set parameters (gradually increase or reduce vibrating frequency from starting frequency to stop frequency). The sweep frequency speed is decided by its time. Operating mode is shown in figure b. The test frequency and amplitude must be within the machine’s performance curve, or it cannot be tested.
iii) Multi-stage frequency test mode: individually set multiple (at most ten stages) test frequency and testing duration (each stage with single frequency test). Then set certain amplitude. The software will control the vibrating table according to the set parameters. The operating mode is shown in figure c. Test frequency and amplitude must be within the machine’s performance curve, or it cannot be tested.
Customer Services
Presales:
In-Sales:
After-Sales:
Mechanical shaker images
![]()
![]()
담당자: Mr. Labtone
팩스: 86-769-85370093